MAINTENANCE PAINTING SYSTEM
C101.4 TIMANTTI 20
Maintenance painting system for ceilings and walls previously painted with acrylate or alkyd paint.
PRETREATMENT
Wash the surfaces with RENSA SUPER Paint cleaner. Remove all loose paint. Matt down hard or gloss surfaces by sanding and thereafter remove the dust.
APPLICATION
Fill the damaged areas with SILORA W Filler. Sand the filled areas and spot paint 2 x with TIMANTTI W Moisture sealer. Finish 2 x with TIMANTTI 20 Special acrylate paint.