TEKNOLINE EP 305

Epoxy phenol novolac paint

  • Corrosion protective
  • Low-temperature curing
  • 2-component
  • Solvent-borne
  • DTM (direct-to-metal)

TEKNOLINE EP 305 is a two-pack epoxy phenol (novolac) primer cured in temperatures from 0°C. It may be used as single paint protection system.

The paint is used as external coating for the protection of insulated (CUI) and uninsulated process pipework and vessels. The coating has very good adhesion to substrates and high temperature resistance (up to 200ºC). Exposed to temperature, the surface may change the shade, without negative effect on the surface properties.

Surface preparation

Remove from the surfaces any contaminants that might be detrimental to surface preparation and application. Remove also water-soluble salts by using appropriate methods. The surfaces are prepared according to the different materials as follows: STEEL SURFACES: Remove mill scale and rust by blast cleaning to preparation grade Sa 2½ (standard ISO 8501-1). The profile of the blast-cleaned surface must be at least coarse (reference comparator "G"). See standard ISO 8503-2 (G). Occasionally, it is allowed to paint on spots cleaned to P St 3 according to PN-EN ISO 8501-2. The place and time of the preparation are to be chosen so that the prepared surface will not get dirty or damp before the subsequent treatment. Additional instructive information for surface preparation can be found in standards EN ISO 12944-4 and ISO 8501-2.

Application

Take into consideration the pot life of the mixture when estimating the amount to be mixed at a time. Before application the base and hardener are mixed in right proportion. Stir thoroughly down to the bottom of the vessel. Wait 15 min (at 23ºC) before use. Mixing by machine is recommended, for example a slow-rotating hand-drill equipped with a mixer. Inadequate stirring or incorrect mixing ratio results in imperfect curing and impaired film properties. Apply by airless spray or brush (brush – only for small surfaces). Airless spray parameter: Nozzle size 0.015 - 0.019". Nozzle pressure 10-15 MPa. When preparing painting specification, depending on subject and type of construction, different dry film thickness than recommended can be assumed. During airless spray application typical dry film thickness range is between 80 and 300 µm. Different dry film thickness than recommended causes change in theoretical spreading rate, wet film thickness, weight of dry film thickness, drying time, overcoating time and ready for handling time. It should be remembered that increasing the degree of cleanliness of the substrate extends the durability of the paint coating.

Application conditions

During the application and drying period the temperature of the ambient air shall be above 0°C and the relative air humidity below 80%. The minimum temperature of the paint should be +15°C. Additionally, the temperature of the surface to be treated and the product must be at least +3°C above the dew point of the ambient air. Adequate ventilation during application and drying period is recommended.

Storage

The storage stability is shown on the label. Store in a cool place and in tightly closed containers.
Total mass of solids abt. 1280 g/l
Volatile organic compound (VOC) abt. 350 g/l
Pot life 3 h (+23 °C)
Mixing ratio 8:1 by volume (comp. A : comp. B)
Hardener Comp. B: TEKNOLINE EP HARDENER 7304
Gloss Matt
Practical spreading rate The values depend on the application technique, surface conditions, overspray, etc.
Drying time – dust free after 15 min
Drying time – touch dry after 3 h
Drying time – fully cured after 7 days
Thinner TEKNOSOLV 9506
Clean up TEKNOSOLV 9506
Colours TO-320 sandy, TO-990 black, TO-290- brown, RAL 7035
Safety markings See safety data sheet.